Rewinding is accomplished by giving the rewind order, move tape to load point, MLP. The rewind order starts a unit rewinding and does not tie up the TC. If a motion command is given which calls for a unit that is rewinding, the command is executed, but the action will not take place until the unit is available.
A unit is unavailable to the program under the following conditions:
1. Unit is rewinding. 2. Tape is improperly loaded. 3. Cover door open. 4. Unit overloaded. 5. Unit under manual control. 6. Power off.
A selected but unavailable unit holds up the TC if a motion order is given for the unit. The TC will be held up until the unit is ready.
0 EOR - End of record 1 RWF - Read-Write 2 EOT - End of Tape 3 Parity
The high speed channel directs the tape control, and word transfer, just as a program would. A unit is first started reading or writing. The high speed channel is given the memory location of the information, and the number of registers the words read or written will occupy. The channel effects the information transfer. Thus, a high speed channel connected to a tape control handles the programming for the unit word transfers.
Completion of the block transfer is signified by either setting a program flag, or entering the sequence break.
When the TC is connected to the Sequence Break System, the program is automatically interrupted each time an MPS command needs to be given.
Programming is unaffected during reading and a record may be read with no flags set. The TC initiates breaks so that an MPS may be given in time.
Similarly, the break is initiated during writing each time an MPS needs to be given.
_Time before _Time between _Time after End of _Flags that first MPS_ MPS's_ Record to deselect_ may be set_
MWA 3 ms. 400 us. 10 ms. RWF (if unit MWB (longer time is deselected causes deselection) and MPS given, or unit becomes unavailable), Parity, EOT.
MRA 7 ms. < 400 us. 5 ms. RWF, (if MRB (longer time information misses information, is missed, or and unit becomes rwc set) unavailable), EOT, EOR, Parity.
MBA - - 10 ms. RWF (if unit MBB becomes unavailable), EOR, EOT.
The PDP-3 Cathode Ray Tube Display is useful for presentation of graphical or tabular information to the operator. It uses a 16 inch round tube with magnetic deflection. For each In-Out transfer order, one point is displayed at the position indicated by the In-Out Register. Bits 0-9 of the IO indicate the X coordinate of the position, and bits 18-27 indicate the Y coordinate. The display takes 60 microseconds.