NOTE.—The following list gives the numbers with the corresponding names of the parts of _the surface condenser_, shown in the above outline sketch: 1, condenser shell; 2, outside heads; 3, exhaust inlet; 4, exhaust outlet; 5, water inlet; 6, water outlet; 7, peep holes; 8, tube heads; 9, partition; 10, rib; 11, tubes; 12, stuffing-boxes.

NOTE.—The numbers and names of parts in the above figure, representing in outline a _jet condenser_, are as follows: 1, condenser body; 2, exhaust inlet; 3, discharge; 4, injection valve; 5, spray pipe; 6, spraying device.

Pumps and Hydraulics - Part Two — Part 155

_Steam, however, gives up its heat to a relatively cool surface much more readily than do the hot furnace gases_, and the positively circulated cooling water takes up that heat and keeps the temperature of the surface down, while in a boiler the absorption depends in a great measure upon the ability of the water by natural circulation to get into contact with the surface and take up the heat by evaporization. It has been found, therefore, that a much smaller surface will suffice in a condenser than in the boilers which it serves.

Pumps and Hydraulics - Part Two — Part 155

The Wheeler Condenser and Engineering Company, who make a specialty of surface condensers, say that one square foot of cooling surface is usually allowed to each 10 pounds of steam to be condensed per hour, with the condensing water at a normal temperature not exceeding 75°. This figure seems to be generally used for average conditions. Special cases require special treatment.

Pumps and Hydraulics - Part Two — Part 155

For service in the tropics the cooling surface should be at least ten per cent. greater than this estimate. Where there is an abundance of circulating water the surface may be much less, as with a keel condenser, where 50 pounds of steam is sometimes condensed per hour per square foot of surface; or a water works engine, where all the water pumped is discharged through the condenser and not appreciably raised in temperature, probably condensing 20 to 40 pounds of steam per hour per square foot of surface.

Under the division of this volume devoted to “air and vacuum pumps,” much information has been given relating to the principles of the condensation of steam and also some illustrations of working machines. Still it may be well to say this, in addition, that—