Each reducing valve is placed on a 30-cm. (12-in.) branch main between the two services. These valves adjust themselves automatically to the pressure required, after they have been properly regulated to the different pressures on either side. To allow repairs to be easily made, there are ordinary gate-valves at each end enclosed in the same pit. If necessary, as in case of fire, any part of the system can be changed into high pressure temporarily by closing the valves against the San Geronimo supply.

Table 9 gives the length of the mains as laid, and the number of valves.

ASCE 1193: The Water-Works and Sewerage of Monterrey, N. L., Mexico — Part 49

=========================+=====================+============= DIAMETER: | | --------------+----------+ Length, in meters. | Number of Centimeters. | Inches. | | gate-valves. --------------+----------+---------------------+------------- 10.2 | 4 | 49,831.68 | 677 15.2 | 6 | 31,918.31 | 306 30.5 | 12 | 14,461.31 | 117 38.1 | 15 | 1,661.98 | 11 45.7 | 18 | 4,522.61 | 5 61.0 | 24 | 2,826.54 | 10 76.2 | 30 | 1,454.40 | --------------+----------+---------------------+------------- Totals | 106,676.83 | 1,126 =========================+=====================+=============

ASCE 1193: The Water-Works and Sewerage of Monterrey, N. L., Mexico — Part 49

The pipes were all cast according to the British Standard Specification, in 3.65-m. (12-ft.) lengths, and were supplied by Messrs. D. Y. Stewart and Company, and Messrs. Dick, Kerr and Company, of Kilmarnock and London. The valves were all of standard design, faced with gun-metal, and were supplied by Messrs. Glenfield and Kennedy, Limited, of Kilmarnock, Scotland.

ASCE 1193: The Water-Works and Sewerage of Monterrey, N. L., Mexico — Part 49

In the distribution system it is proposed to provide 200 fire-hydrants, by arrangement with the municipality, but only a few of these have been placed. The general type is a double hydrant for two 63.5-mm. (2-1/2-in.) streams. These are to be placed at the corner of every block in the business portion of the city; single-way hydrants will be used in the residential districts.

_Laying Cast-iron Pipes._--Table 10 has been prepared to show what can be accomplished with Mexican labor in laying pipes. In this kind of work the labor was particularly efficient; after the gangs were once drilled into shape, the work proceeded systematically, and at very good speed. All the pipes, after being laid, were tested to 150 lb. per sq. in. in the presence of the Technical Inspector.