It is perhaps unnecessary to add, that no pipe capable of being melted by a gas flame, should ever be employed for conveying or distributing gas through the interior of houses, because the facility with which such pipes might be perforated, could lead to serious consequences, if the gas issuing from the aperture of the pipe were lighted, the flame in that case would follow the melted part, through the whole extent of the pipe, and the hazard by fire would be considerably increased. Therefore, pewter, lead, and tin pipes, are very improper for distributing gas through the interior of houses, and should never be used for that purpose. Hence copper, and iron pipes, are universally employed.
In order that the pipes for conveying the gas from the mains, and distributing it through the houses or other buildings to be lighted with gas, may in the first place not be unnecessarily large, or too small, the following rule may serve as a guide to workmen:
One gas lamp,--consuming four cubic feet of gas in an hour, if situated twenty feet distance from the main which supplies the gas, requires a tube not less than a quarter of an inch in the bore.
Two lamps,--30 feet distance from the main, require a tube ³⁄₈ of an inch in the bore.
Three lamps,--30 feet distance from the main, require a tube ³⁄₈ of an inch in the bore.
Four lamps,--40 feet distance from the main, require a tube ¹⁄₂ inch in the bore.
Six lamps,--50 feet distance from the main, require a tube ⁵⁄₈ of an inch in the bore.
Ten lamps,--100 feet distance from the main, require a tube ³⁄₄ of an inch in the bore.
Fifteen lamps,--130 feet distance from the main, require a tube 1 inch in the bore.
Twenty lamps,--150 feet distance from the main, require a tube 1¹⁄₄ inch in the bore.
Twenty-five lamps,--180 feet distance from the main, require a tube 1⁵⁄₈ of an inch in the bore.
Thirty lamps,--200 feet distance from the main, require a tube 1¹⁄₂ inch in the bore.
Thirty-five lamps,--250 feet distance from the main, require a tube 1⁵⁄₈ of an inch in the bore.
All copper pipes employed to convey gas through the interior of houses should be of the following weight, with regard to a given length of the pipe:
_Bore of the pipe._ _Weight per foot._ PARTS OF AN INCH. OUNCES. ²⁄₈ 3 ³⁄₈ 5 ¹⁄₂ 6 ⁵⁄₈ 8 ³⁄₄ 10