137. TESLA’S EXPERIMENTS. _Elec. Rev._, N.Y., March 11, ’96, page 131, March 18, page 147, April 1, page 171, and April 8, page 183. KIND OF ELECTRICAL APPARATUS FOR OPERATING DISCHARGE TUBES FOR POWERFUL X-RAYS. § 106, 109, 114, 131. The experiments performed by Nikola Tesla were particularly noteworthy for the magnitude and intensity of the rays generated by his apparatus, under his skilful manipulation of the adjustments and circuits particularly as to resonance. The remarkable results that he obtained are not surprising when we learn that he employed his well-known system for producing exceedingly enormous potential and unusually high frequency. § 51. The primary electrical generator as he indicated and as apparent from his system referred to in the above section, could be either a direct or alternating current generator, or other form. If the first is employed, of course an interrupter is necessary in order that there may be a current induced in the secondary.

Roentgen Rays and Phenomena of the Anode and Cathode. — Part 103

SCIAGRAPH OF RAT, TAKEN BY OLIVER B. SHALLENBERGER WITH FOCUS TUBE (CUT AT p. 81) AND TESLA SYSTEM. § 137, pp. 136 and 138. ]

Roentgen Rays and Phenomena of the Anode and Cathode. — Part 103

Mr. Oliver B. Shallenberger, (_Mem. Amer. Inst. Elec. Eng._) whose laboratory is in Rochester, Pa., gave some important general instructions concerning the Tesla system § 51, that he employed in the production of remarkably clear sciagraphs, in conjunction with the focus tube, § 91, representing the hand at page 68, and showing a rat shown at this § 137. (_Elec. World_, N.Y., March 17, ’96.) Even the ligaments were clearly shown in the sciagraph of the rat, and some of them are dimly reproduced by the half tone process. As to the apparatus and operation, which are especially important, it may be stated that the current was taken from an alternator, of a frequency of 133 periods per second, and passed through a primary coil of a transformer for increasing the E. M. F. from 100 volts to from 16 to 25 thousand. The secondary current was then passed through Leyden jars and a double cascade of slightly separated brass cylinders, whereby it was changed into an oscillatory current of an extremely high frequency, which was then conducted through the primary of a second induction coil having very few turns of wire, and no iron core and having a ratio of 7 to 1. By this means the E. M. F. was raised to somewhere between 160,000 volts to 250,000, and was used to energize the discharge tube for the generation of X-rays. Caution should be taken, because the current coming from the first transformer, being of large quantity and very high E. M. F. is exceedingly dangerous, but the current of the second secondary has been passed through one’s body without danger, as reported by Mr. Tesla several years ago, and confirmed by Mr. Shallenberger.

Roentgen Rays and Phenomena of the Anode and Cathode. — Part 103