The arterial resistivity index (also called as Resistance index, abbreviated as RI), developed by Léandre Pourcelot , is a measure of pulsatile blood flow that reflects the resistance to blood flow caused by microvascular bed distal to the site of measurement.

Calculation

The formula used to calculate resistance index is:

Arterial resistivity index

Description

The RI is altered not by vascular resistance alone but by the combination of vascular resistance and vascular compliance.

Arterial resistivity index

Normal mean renal artery RI for an adult is 0.6 with 0.7 the upper limit of normal. In children, RI commonly exceeds 0.7 through 12 months of age and can remain above 0.7 through 4 years of age.

Arterial resistivity index

Uses

Medical ultrasonography

It is used in ultrasound testing of umbilical artery for placental insufficiency. RI should not exceed 0.60 at 30 weeks of gestation. RI is also commonly used to monitor kidney status, especially following kidney transplant. Following kidney transplantation, patients with an RI > 0.8 have an increased mortality.

Medical laser Doppler imaging

Mapping of the local arterial resistivity index from laser Doppler imaging enables unambiguous identification of retinal arteries and veins on the basis of their systole-diastole variations, and reveal ocular hemodynamics in human eyes.